Autoclaved Aerated Concrete

Construction and Consultation Services

homecontact ussite map


Autoclaved Aerated Concrete is the safest material for fire protection.

AAC is classified as a non-combustible building material.

Some insurance companies offer reductions in fire premiums for buildings equipped with AAC fire walls.

contact us

fire ball




Autoclaved Aerated Concrete's Fire Resistance

Autoclaved Aerated Concrete Product Line Approvals and Standards

ICC ESR-1371 Autoclaved Aerated Concrete (AAC) Block Masonry Units Download Report Evaluation Report of E-Crete AAC Walls
   
ICC-ES PFC-3700 Autoclaved Aerated Concrete (AAC) Reinforced Precast Panel and AAC Block Masonry Units Download Report Legacy Report on Aercon AAC floor, roof, and wall systems
   
Underwriters’ Laboratories (UL) Design Numbers: U916, U917, U921, U919, X901 Fire Test Results for AAC Walls
   
Underwriters’ Laboratories (UL) Design Number: U924 Sound Transmission Class (STC) For AAC Walls

page break

Standards

ASTM C 1386
Standard Specification AAC Units

Standard Covers Physical Requirements of Loadbearing Compression and Non-Loadbearing AAC Units
   

ASTM C 1555-03
Standard Practice for Autoclaved Aerated Concrete Masonry 1

Standard covers workmanship of AAC, thin bed mortars, and exterior and interior finishes.
ASTM E 119 Fire Test of Building Constructions and Materials WATCH VIDEO Fire Test of Wall Assemblies (Load and Non-Loadbearing) and Hose Stream Test. Fire Test of Floor and Roof Assembly
   

ASTM E 90-97, E 413-87 and C 423-99a - Sound Transmission Loss Test (STC)

Airborne Sound Transmission Test on Walls
   

ASTM C-469
Modulus of Elasticity

Airborne Sound Transmission Test on Walls
   

ASTM E-78
Flexural Strength

Flexural Test of AAC Units To Determine Flexural Strength
   

ASTM E-518
Flexural Bond Strength of Masonry

Assembly of Masonry Units Constructed as Beams
   

ASTM E-519
Diagonal Tension Test of Masonry Assemblies

Full Scale AAC Walls To Determine Shear Strength
   

ASTM C-177-85
Standard Test Method for Steady-State Heat Flux Measurements and Thermal Transmission Properties by Means of the Guarded Hot Plate Apparatus

A Portion of AAC Material of 12 x 12 inch and 1 inch Thick is Placed in the Guarded Hot Plate. It Is Subjected to a Heat Source and Temperature Measurements are Made Until a Steady State is Reached. This test is used to determine experimental value as thermal conductivity (K) on AAC units.
   
ICC-ES AC215 Seismic Design Criteria Download Report Acceptance Criteria Report providing seismic design factors and coefficients for AAC.
   